TH series Touchscreen User Manual Page 73 of 81 MANUL018R2V1
Step3: double click “import CSV data”.
Import tab:
Save tab:
Control tab:
Device ID: 1
Path/File: SJDR.csv, must be the
same as the object import file.
Fix name means importing from the
same file.
Start ID: dynamic appoint PSW500.
Register capacity: 10, it means 10
groups of data
Register mode: line
Add the title: there are 4 rows of data.
Object: save the data of mobile device
into TH register starts from PSW400.
Execute status: PSB300 to show the importing
state
Execute result: PSW256 to show the importing
result
Execute process: PSW257 to show the
importing process