119
Parameter
Name
Range
P5-11
Voltage acceleration time of VF separation
0.0s~1000.0s
Note: it indicates the time when 0V changes
to the motor rated voltage
P5-12
Voltage deceleration time of VF
separation
0.0s~1000.0s
Note: it indicates the time when 0V changes
to the motor rated voltage
The voltage rise time of VF separation refers to the time required for the output voltage to accelerate from 0 to
the motor rated voltage, as shown in t1 in the figure below.
The voltage drop time of VF separation refers to the time required for the output voltage to decelerate from the
motor rated voltage to 0, as shown in t2 in the figure below.
Parameter
Name
Range
P5-13
Stop mode of VF separation
0: Frequency voltage independently reduced
to 0
1: When the voltage decreases to zero, the
frequency begins to decrease
0: Frequency voltage independently reduced to 0
The output voltage of VF separation decreases to 0V according to the voltage drop time (P5-12). The output
frequency of VF separation decreases to 0Hz according to deceleration time (P0-19).