133
0: No display
1: Display user modified parameters
When P8-05=10, press JOG button to enter --C--, check the parameters modified by user.
To return to the parameter adjustment interface, press JOG button, press ENT in the interface where "-- A --" is
displayed on the panel.
When P8-05=01, press JOG button to enter --U--, check the parameters defined by user. User can select
common parameters through group PE (PE-00~PE-31). Please refer to chapter 3-1-6 for details.
When P8-05=10 is set, press, and press ENT on the panel display "-- C --" interface to view the parameters
modified by the user. To return to the parameter adjustment interface, press, and press ENT in the interface
where "-- A --" is displayed on the panel
When P8-05=01, press, and press ENT on the panel display "-- U --" interface to view user-defined parameters.
The user can select common parameters by PE group (PE-00~PE-31).
Parameter
Name
Range
P8-06
Parameter modification attribute
0: Modifiable
1: Not modifiable
Users can set whether the function code parameters can be modified to prevent the risk of function parameters
being changed by mistake.
If the function code is set to 0, all function codes can be modified; When it is set to 1, all function codes can
only be viewed and cannot be modified.
Parameter
Name
Range
P8-07
LED operation display parameter 1
0000 ~ FFFF
P8-08
LED operation display parameter 2
0000 ~ FFFF
Bit definition
P8-07