171
Parameter
Name
Min unit
U0-18
Actual encoder feedback speed (Hz)
Depend on P8-22
Display the actual encoder feedback motor speed, unit: Hz.
Parameter
Name
Min unit
U0-19
Line speed
1m/Min
Display X4 high-speed pulse sampling line speed, which is calculated from the actual number of sampling
pulses per minute and A0-02 function code.
Parameter
Name
Min unit
U0-20
PLC stage
1
When using the simple PLC function, monitor the current number of operating segments, parameter PB group
parameter settings.
Parameter
Name
Min unit
U0-21
Count value
1
U0-22
Length value
1
When using the inverter counting and length fixing functions to view the count value and length value received
by the sent frequency converter. Refer to A0 group parameter description.
Parameter
Name
Min unit
U0-23
Main frequency A display
0.01Hz
U0-24
Auxiliary frequency B display
0.01Hz
Display the set values of main and auxiliary frequency.
Parameter
Name
Min unit
U0-25
Communication setting
0.01%
Display the value written in the H1000 through modbus communication.
Parameter
Name
Min unit
U0-26
AI1 voltage(V)/current (mA) before calibration
0.001V/0.01mA
U0-27
AI2 voltage(V)/current (mA) before calibration
0.001V/0.01mA
U0-28
AI3 voltage(V)/current (mA) before calibration
0.001V/0.01mA
Display the actual value of analog input sampling voltage / current.
The actually used voltage / current has been linearly corrected to make the deviation between the sampled
voltage / current and the actual input voltage / current smaller.
Monitor U0-09, U0-10, U0-11 for the actually used correction voltage / current.
Parameter
Name
Min unit
U0-29
Remaining running time
0.1Min
Display the remaining running time when the timing function is running. Refer to PC group timing function
parameter settings.
Parameter
Name
Min unit
U0-30
Present power on time
1Min
U0-31
Present operation time
0.1Min
Display the power on time and running time of this power on. This parameter is not memorized when power is