172
off.
Parameter
Name
Min unit
U0-33
Present fault
1
The current fault code is displayed.
Parameter
Name
Min unit
U0-35
Target torque (%)
0.1%
When PF-01 selects 0, U0-35 is the same value with PF-02.
Parameter
Name
Min unit
U0-36
Torque upper limit
0.01%
In torque mode, display the current torque value.
In speed mode, display the given torque upper limit value.
Parameter
Name
Min unit
U0-37
Synchronous motor rotor position
1
Displays the current position of the synchronous motor rotor.
Parameter
Name
Min unit
U0-38
Rotary transformer position
1
U0-39
ABZ position
1
Display the current position signal of rotary transformer.
The display encoder displays the AB phase pulse count of the current ABZ or UVW encoder.
Parameter
Name
Min unit
U0-41
Power factor angle
0.1°
Parameter
Name
Min unit
U0-42
Setting frequency (%)
0.01%
U0-43
Operation frequency (%)
0.01%
The current setting frequency and operating frequency are displayed, and 100.00% corresponds to the maximum
frequency of the inverter P0-13.
Parameter
Name
Min unit
U0-44
VF separate target voltage
1V
U0-45
VF separate output voltage
1V
Display the target output voltage and current actual output voltage when running in VF separation state. Refer
to Group P5 VF separation parameter settings.
Parameter
Name
Min unit
U0-46
Z signal counter
1
Displays the Z-phase pulse count of the current ABZ or UVW encoder.
It can help detect whether the encoder is installed normally.
When the encoder rotates one circle in the forward direction, the value of U0-46 increases by 1.
When the encoder rotates one circle in the reverse direction, the value of U0-46 decreases by 1.
Parameter
Name
Min unit
U0-47
Motor serial number
0: motor 1
1: motor 2