66
Group P7: Fault parameters
Parameter
Name
Setting range
Default
value
Modify
Modbus
address
P7-44
Number of automatic reset of faults
0~20
0
072CH
P7-45
Protection action selection 1 when
fault
Ones bit: motor overload (Err 10)
0: Free stop
1: Stop as stop mode
Tens bit: input phase lacking (Err11)
0: Free stop
1: Stop as stop mode
Hundreds bit: output phase lacking
(Err12)
0: Free stop
1: Stop as stop mode
Thousands bit: output load drop
(Err19)
0: Free stop
1: Stop as stop mode
Ten thousand bit: pole position
detection failed (Err21)
0: Free stop
1: Stop as stop mode
00000
072DH
P7-46
Protection action selection 2 when
fault
Ones bit: external fault 1 (Err43)
0: Free stop
1: Stop as stop mode
Tens bit: communication error
(Err44)
0: Free stop
1: Stop as stop mode
Hundreds bit: EEPROM read write
error (Err45)
0: Free stop
1: Stop as stop mode
Thousands bit: operation time
reached (Err46)
0: Free stop
1: Stop as stop mode
Ten thousand bit: power on time
reached (Err47)
0: Free stop
1: Stop as stop mode
00000
072EH
P7-47
Protection action selection 3 when
fault
Ones bit: user defined fault 1
(Err48)
0: Free stop
1: Stop as stop mode
Tens bit: user defined fault 2 (Err49)
00000
072FH