89
Group U0: monitor parameters
Parameter
Name
Min unit
Modbus address
Display range
Bit3: Frequency
reaches the set
frequency
(supported by 3720
and above versions)
Bit8~Bit15: Alarm
code(supported by
3720 and above
versions)
U0-70
Communication feedback motor speed
/0.01Hz
0.01Hz
7046H
-
U0-71
Communication feedback motor speed
/RPM
1RPM
7047H
0~rated speed
U0-72
Special current display for
communication card
-
7048H
-
U0-73
Communication card error status
-
7049H
-
U0-74
Motor actual output torque
0.01%
704AH
-200.00% ~
200.00%
U0-75
Fault code
0
704BH
0~56
U0-76
Operation status word
Bit0:
0: shutdown
1: in operation
704CH
0x0000~0xFFFF
Bit1:Normal
operation
Bit2: Jog operation
Bit3:Tuning
operation
Bit4:Jog during
operation
Bit5~Bit6: running
state
00: Constant speed
process
01: Acceleration
process
10: Deceleration
process
Bit7:PLC operation
Bit8:PID operation
Bit9:Torque control
Bit10:Set
frequency direction
Bit11:Current
frequency

Table of Contents