OVEN TROUBLESHOOTING
LUI Service Error Codes
Display Alarm MC LED
Error Determination Troubleshooting
Oven Probe
Temp Sensor Error, Open or Short.
Temp <40F (4C) or >700F (371C)
Perform A Hard Reset. If Error Still Exists,
Contact XLT.
PCB Temp Probe
Temp Sensor Error, Open or Short.
Perform A Hard Reset. If Error Still Exists,
Contact XLT.
Ignition Error
From Ignition enable (run) signal, if
oven doesn’t see 25F (-4C) temp
rise in three (3) minuites. If restart
(actual temp within 50F (10C) of set
point) error timing ten (10) minutes.
Check To See If Gas Hose Is Connected.
Next, Is Exterior Gas Valve On? If Yes,
Perform A Hard Reset. If No, Turn Gas
Valve On. If Error Still Exists, Contact XLT.
Over Temp
Temp is 50F (10C) over set point
for period > one (1) minute. If user
adjusts set point lower, inhibit alarm
until new set point is reached.
Perform A Hard Reset. If Error Still Exists,
Contact XLT.
Under Temp
Once set point is reached, the Actual
is 15F (-9C) under set point for
more than thirty (30) minutes. If user
adjusts set point, reset timer.
Check To See If Gas Hose Is Connected.
Next, Is Exterior Gas Valve On? If Yes,
Perform A Hard Reset. If Error Still Exists,
Contact XLT.
Over Speed
Speed > thirty (30) seconds fast
Duration vs. Set Point
Perform A Hard Reset. If Error Still Exists,
Check LUI Settings. If Settings Are Correct,
Perform A Pan Test To Confirm Settings. If
Error Still Exists, Contact XLT.
Under Speed
Speed > thirty (30) seconds slow
Duration vs. Set Point
Check Drive Chain and Sprocket To Verify
Proper Working Condition. Perform A Hard
Reset. If Error Still Exists, Check LUI
Settings. If Settings Are Correct, Perform A
Pan Test To Confirm Settings. If Error Still
Exists, Contact XLT.
Software Error
Internal Software Error
Check for pinched wires. Perform A Hard
Reset. If Error Still Exists, Contact XLT.
EEPROM Error
Bad Checksum
Perform A Hard Reset. If Error Still Exists,
Contact XLT.
Key Short
Any Key Shorted > one (1) minute.
Clean LUI Screen. Perform A Hard Reset.If
Error Still Exists, Contact XLT.
Comm Error
Internal Software Error
Perform A Hard Reset. If Error Still Exists,
Contact XLT.
Hi Alarm
Hi Alarm set point exceeded.
Perform A Hard Reset. If Error Still Exists,
Contact XLT.
Main Fan Low
Amps
Amps below min level per Main Fan
Amp level table for ten (10) seconds.
Perform A Hard Reset. If Error Still Exists,
Contact XLT.
Main Fan High
Amps
Amps above max level per Main Fan
Amp level table for ten (10) seconds.
Check CB1 To See If It Has Tripped. If Yes,
Reset CB1. If No, Perform A Hard Reset. If
Error Still Exists, Contact XLT.
Belt Jam
If the current motor speed is less
than 25% of the most recent
minimum motor speed.
Check For Obstructions. If No Obstructions
Are Found, Check Drive Chain and Sprocket
To Verify Proper Working Condition.
Perform A Hard Reset. If Error Still Exists,
Contact XLT.