OVEN SERVICE PROCEDURES
Invertek VFD (World) Programming Procedure
Read the entire instruction before programming.
TIP
Programming Instructions For Factory Parameters
1. Press and hold NAVIGATE > 2 seconds.
2. Press UP Arrow until (P-14) is displayed and press NAVIGATE.
3. Press UP Arrow until (201) is displayed and press NAVIGATE to save and return to parameter
menu.
4. Press UP Arrow until (P-15) is displayed and press NAVIGATE.
5. Press UP Arrow until (2) is displayed and press NAVIGATE to save and return to parameter menu.
6. Press UP Arrow until (P-17) is displayed and press NAVIGATE.
7. Press UP Arrow until (24) is displayed and press NAVIGATE to save and return to parameter
menu.
8. Press UP Arrow until (P-20) is displayed and press NAVIGATE.
9. Press DOWN Arrow until (0.0) is displayed and press NAVIGATE to save and return to parameter
menu.
10. Press UP Arrow until (P-21) is displayed and press NAVIGATE.
11. Press UP Arrow until (60.0) is displayed and press NAVIGATE to save and return to parameter
menu.
12. Press UP Arrow until (P-51) is displayed and press NAVIGATE.
13. Press UP Arrow until (1) is displayed and press NAVIGATE to save and return to parameter menu.
14. Press DOWN Arrow until (P-38) is displayed and press NAVIGATE.
15. Press UP Arrow until (1) is displayed and press NAVIGATE to save and return to parameter menu.
16. Press and hold NAVIGATE > 2 seconds to return to operating display.
With the Oven Control switched off and power connected to the oven, the VFD should show
Stopon the display.
Do Not Exceed 65 Hz On VFD Settings.
START
When in keypad mode, used to Start a stopped
drive or to reverse the direction of rotation if bi
-directional keypad mode is enabled.
UP
Used to increase speed in real-time mode or to
increase parameter values in parameter edit
mode.
DOWN
Used to decrease speed in real-time mode or to
decrease parameter values in parameter edit
mode.
NAVIGATE
Used to display real-time information, to ac-
cess and exit parameter edit mode and to store
parameter changes.
RESET/STOP
Used to reset a tripped drive.
When in Keypad mode, used to Stop a running
drive.