EasyManua.ls Logo

XLT Ovens X3F3-1832 Series - Oven Operator Controls; Software and Serial Number Information; Belt and Fan Settings

XLT Ovens X3F3-1832 Series
118 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Support US: 888-443-2751 Technical Support INTL: 316-943-2751
36
OVEN OPERATOR CONTROLS
Software Version
MC & UI Software Version. Press Down arrow to go to next screen.
Image For Reference Only - See XLT For Correct Version.
Serial Number
ENTER button to make changes. Use side to side arrows to scroll to next character
position. Use Up/Down arrows to change values and press ENTER to accept and ad-
vance.
Elapsed Time
Elapsed time “Total Operation” and “Since Last Filter Cleaning”. Elapsed time total
cannot be reset. Press ENTER to advance.
Belt Length
There are four available belt lengths: 32, 40, 55 and 70 with the default set at 55. EN-
TER to highlight value, arrows up/down to adjust. ENTER to accept and advance.
Belt Width
There are four available belt widths that correspond with the length selected. The default
is set at 32. If a belt length of 32 is chosen, then the only option is a 18 belt width. If 40
is chosen, then you can select 24 or 32. If a 55 or 70 is chosen, then you can select 32 or
38. ENTER to highlight value, arrows up/down to adjust. ENTER to accept and advance.
Main Fan Type
Factory default is On/Off type. To change, press ENTER key. Use Up/Down arrows to
change between STD and VFD. Press ENTER to accept and advance.
Split Belt
MC1 is for left belt and MC2 is for right belt. Factory default is NO. To change press
ENTER. Use Up/Down arrows to change to YES (still flashing). Press ENTER to ac-
cept and advance.
Dual Burner
MC1 is for the Right Hand Burner and MC2 is for the Left Hand Burner. Factory de-
fault is NO. To change press ENTER. Use Up/Down arrows to change to YES (still
flashing). Press ENTER to accept and advance. If MC2 doesn't have a jumper error will
show.
Factory Tech Mode
To enter Factory Tech Mode press and hold the 2 arrow buttons for 10 seconds.
TIP
Read and understand steps first. Screens will auto exit if no activity is sensed.