Technical Support US: 888-443-2751 Technical Support INTL: 316-943-2751
91
HOOD OPERATOR CONTROLS
Factory Tech Mode
1. To enter Factory Tech Mode press and hold 2 butons <HOOD LIGHT> and <XLT LOGO> for
10 sec. to enter.
2. Displays will show message for 3 sec. and beep, auto-advance.
Software Version
MC & UI Software Version. Press Down arrow to go to next screen.
Image For Reference Only - See XLT For Correct Version.
Serial Number
ENTER button to make changes. Use side to side arrows to scroll through the menu.
Use Up/Down arrows to change values and ENTER to accept and advance.
Belt Length
There are four available belt lengths: 32, 40, 55 and 70 with the default set at 55. EN-
TER to highlight value, arrows up/down to adjust. ENTER to accept and advance.
Belt Width
There are four available belt widths that correspond with the length selected. The default
is set at 32. If a belt length of 32 is chosen, then the only option is 18 belt width. If 40 is
chosen, then you can select a 24 or 32. If a 55 or 70 is chosen, then you can select a 32 or
38. ENTER to highlight value, arrows up/down to adjust. ENTER to accept and advance.
Elapsed Time
Elapsed time total operation. Elapsed time total cannot be reset. Press ENTER to ad-
vance.
Cooling Filter
Elapsed time since Cooling Filter cleaned. Resets when customer resets it. Press the
Error Information button to reset time if needed. Hour Interval is a service tech refer-
ence. Press Down arrow to advance.
Grease Filter
Elapsed time since Grease Filters cleaned. Resets when customer resets it. Press the
Error Information button to reset time if needed. Hour Interval is a service tech refer-
ence. Press Down arrow to advance.