Alert and Warnings
The pump displays all alerts and warnings on the control panel. When an alarm or warning condition
exists, the corresponding LED will be lit on the display. All control panel buttons are dis
abled until the
alarm or warning is acknowledged with the ENTER button. move the power until the display off.
POWER OUT FAILURE-
Incoming supply voltage is les
s than 190 VAC.
PRIMINZG ERROR-
If the pump is not defined as primed within the maximum priming time it will stop
and generate a priming alarm for 10 minutes, then attempt to prime again. If the pump cannot prime
within 5 attempts it will generate a permanent alarm and have to be manually reset.
OVERHEAT ALERT
- If the drive temperature gets over 103 Degrees Fahrenheit the pump will slowly
reduce speed until the temperature condition clears.
OVER CURRENT
- Indicates that the drive is overloaded or the motor has an electrical problem. The
drive will restart after to over current condition clears.