These requirements and instructions only apply when the installation is made according to
the dimensional drawing.
1. Run the cable so that it has no sharp bends. Make sure that it is not pinched, and
cannot be sucked into the pump inlet.
2. Connect the discharge line.
3. Lower the pump into the sump.
4. Place the pump on the base and make sure it cannot fall over or sink.
Alternatively, the pump can be suspended with a lifting chain just above the sump
bottom. Make sure that the pump cannot rotate at startup or during operation.
5. Connect the motor cable and the starter and monitoring equipment according to the
separate instructions.
Make sure that the impeller rotation is correct. For more information, see Check the
impeller rotation (page 23).
Install with T/Z-installation
In the T-installation, the pump is installed in a vertical position in a dry well next to the wet
sump. These requirements and instructions only apply when the installation is made
according to the dimensional drawing.
The pump for T-installation has a watertight motor that is protected in the event of flooding
in the pump room. The pump is liquid cooled.
The Z-installation is not used for the 3060 pump.
WS006272A
Figure 4: T-installation
These items are required:
Support stand and anchor bolts for anchoring the pump to a base
Shut-off valves that allow you to remove the pump from service
Air vent on the discharge side between the pump and the check valve
NOTICE:
The risk of freezing is particularly high in T- or Z-installations.
1. Fasten the pump: