EasyManua.ls Logo

Xylem Flygt 3060 - Technical Reference; Application Limits; Motor Data; Specific Motor Data

Xylem Flygt 3060
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Reference
Application limits
Data Description
Media (liquid)
temperature
Standard temperature version: Maximum temperature 40°C (104°F)
Warm media (liquid) version: Maximum temperature 70°C (158°F)
Warm media (liquid) version with external cooling: Maximum temperature 90°C
(195°F)
Warm liquid has certain operational limitations, which are stated on a plate on the
pump.
pH of the pumped media
(liquid)
0–14
Media (liquid) density Maximum density: 1100 kg/m
3
(9.2 lb. per US gal.)
Depth of immersion 20 m (65 ft.)
Other For specific weight, current, voltage, power rating, and speed of the pump, see the data
plate on the pump. For starting current, see Motor data (page 35).
For other applications, contact the local sales and service representative for
information.
Motor data
Feature Description
Motor type Squirrel-cage induction motor
Frequency Standard version: 50 or 60 Hz
Supply 1-phase or 3-phase
Starting method Direct on-line
Maximum starts per
hour
30 evenly spaced starts per hour
Code compliance IEC 60034-1
Rated output variation ±10%
Voltage variation without
overheating
±10%, provided that it does not run continuously at full load
Voltage imbalance
tolerance
2%
Stator insulation class H (180°C [360°F])
Specific motor data
Technical Reference
Flygt 3060 Installation, Operation, and Maintenance Manual 35

Table of Contents