6.5.3 Replace the M-impeller
WS006137A
Figure 22: M-impeller
6.5.3.1 Remove the M-impeller
CAUTION: Cutting Hazard
Worn parts can have sharp edges. Wear protective clothing.
1. Remove the pump housing.
2.
Remove the impeller screw and outer sleeve.
If applicable, use the rod.
WS001977A
3. Refit the impeller screw.
6 Maintenance
Flygt 3102 Installation, Operation, and Maintenance Manual 57