EasyManua.ls Logo

Xylem Flygt FGC 421 - Technical Reference; Dimensions; Environmental Requirements; IP-Rating

Xylem Flygt FGC 421
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 Technical Reference
12.1 Dimensions
WS009292A
1 3
2
4
1. 255 mm (10 in)
2. 155 mm (6.1 in)
3. 105 mm (4.1 in)
4. 57.5 mm (2.26 in)
12.2 Environmental requirements
Parameter Value
Operating temperature FGC 401: -20°C – +70°C (-4°F – 158°F)
FGC 411, FGC 421: -20°C – +45°C (-4°F –
113°F)
Storage temperature -20°C – +85°C (-4°F – 185°F)
Operating humidity Relative humidity, non-condensing: 90%
Sunlight exposure UV-resistant
Maximum altitude With UL approval: 2000 m (6562 ft)
Without UL approval: 4000 m (13 123 ft)
12.3 IP-rating
IP20
12.4 Electrical data
Parameter Value
Supply voltage 3-phase:
200–460 VAC with neutral
400–415 VAC without neutral
1-phase: 100–265 VAC
Frequency 50 Hz or 60 Hz
Supply voltage tolerance ± 10%
12 Technical Reference
Flygt FGC 400 Installation, Operation, and Maintenance 55

Table of Contents

Related product manuals