EasyManua.ls Logo

Yale HSA3600 - Component Placement Details; Siren Placement

Yale HSA3600
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
Smoke detector accessory
• Mount on the ceiling at the top of a
stairwell, or where smoke would most
likely be detected
• Install additional detectors if there are
closed doors preventing smoke from
reaching detectors
PIR movement detector
• Mount in a position such that an intruder would
normally move across the PIRs field of view
• Height should be between 1.7 and 2.3 metres
above floor level
• Location in a corner will ensure wider room
coverage
• Do not mount the PIR where its field of view will
be obstructed e.g. by curtains, ornaments etc
• Do not point directly at sources of heat e.g. fires or
boilers, and do not position directly above radiators
•Avoid mounting the PIR directly facing a window
• Do not point the PIR at a door protected by a
door/window contact
Keyfob remote control accessory
Can be used inside or outside the
property and can be kept on your keyring.
Door/Window contact
Select a door that will be the main point
of entry and exit, usually your front door.
• Mount as high as possible
• Do not aim a PIR at this door or window
Siren
Choose a position on an external wall
where the siren would be most prominent.
Mount as high as possible, out of easy reach.
Control unit
• Ensure the control unit is accessible when
entering through a protected entry/exit
point
•Avoid mounting the control unit where it
would be visible from the outside of the
premises
•Wall mounted