Electronic Control System: Technical Manual for 6LY3 Series Engines
Speci cations
Operating Temperature: -18°C (0°F) to +70° C (+158°F).
Storage Temperature: The Storage Temperature range is -40° Centigrade (-40°F) to +80° Centigrade (+176°F
Humidity: Perform 100-hour humidity test per Section 24.7.4 of ABYC P-24.
Salt Spray Atmosphere: Perform 300 hours of salt fog per ASTM B117.
Water Resistance (Hose Down): The gauges and SIM shall not allow any water to enter any of the enclosures when exposed
to 100 liters of water per minute for three minutes per component using a 12.5 mm nozzle. The water shall be directed to all
exposed surfaces during the three-minute test. SAE J1455 Section 4.4.3
Immersion: The gauges and SIM shall be tested per IEC 60529 (IP67) and/or SAE J1171 immersion.
Fogging: Gauge lens shall meet or exceed the criteria speci ed in J1810, Lens Fogging (Indicating Unit).