Yashica FX-3 - Mirror and Shutter Troubleshooting; Mirror Movement Faults

Yashica FX-3
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Shutter
shaft
Phenomenon
When
gently
returning
the
winding
lever,
the
winding
shaft
and
the
set
cam
fixer
do
not
return
all
the
way,
so
that
the
shutter
cannot
be
released.
[T
^
Cause
/3
There
is
no
upward
or
downward
play
in
the
1
winding
stopper
and
the
set
cam.
\
o/
The
holes
of
A-gear
holder
and
the
winding
shaft
holder
into
which
the
winding
shaft
is
put
do
not
agree
with
each
other.
Set
cam
fixer
There
is
no
play
in
the
winding
shaft
and
A-gear
base,
and
no
allowance
is
provided
for
winding
shaft,
holder
inclination
of
the
shaft.
Nv
Repairing
technique
and
confirming
method
Unless
no
play
is
provided
upward
and
down-
/
^
—i
ward,
remove
the
winding
lever
and
lightly
/
/
O
^
strike
the
winding
lever
shaft
from
above
to
1
\\
^
create
a
play.
/
'0^
Loosen
3
screws
of
the
winding
shaft
holder,
/
^
and
again
tighten
the.
3,
screws
at
.the
position
.
_
_
where
the
winding
shaft
rotates
smoothly.
Faults
that
may
occur
The
winding
lever
does
not
return.
SR
lock
lever
Winding
lever
o
SM
set
lever
o
Shutter
cannot
be
released
Phenomenon
Concurrently
with
winding,
the
mirror
moves
up.
Causes
QRL-6
SP
is
released
from
QRL-6,
so
that
QRL
becomes
free
and
as
a
result,
MCL-2
cannot
be
set.
The
part
by
which
QRL-6
SP
is
connected
to
QR
shaft-5
is
short
so
that
QRL-6
SP
is
disengaged
during
operation.
Reparimr
technique
and
confirming
method
&-r
sure
to
connect
the
hook
of
QRL-6
SP
to
Lie
notch
for
engagement
of
QRL-6
SP.
When
installing
QRL-6
SP,
in
order
to
prevent
any
deformation
of
it,
confirm
that
there
is
a
room
that
the
part
where
the
spring
is
engaged
to
QR
shaft-5
can
allow
QRL-6
to
move
smoothly.