EasyManua.ls Logo

Yashica FX-3 - Counter Resetting Faults; Counter Resetting Issues

Yashica FX-3
33 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Phenomenon
When
the
counter
counts
36
frames
or
less
and
,
,
on
Counter
release
lever
SP
then
the
back
cover
is
opened,
the
counter
is
not
reset.
Cause
1.
When
forcibly
tightening
the
counter
G-1
before
it
completely
enters
the
hole
in
case
the
counter
base
is
installed,
burrs
are
pro¬
duced,
so
that
malfunction
of
the
counter
G-1
is
caused.
Z
The
counter
release
SP
is
clamped
by
the
counter
base
SS
with
the
result
that
malfunc¬
tion
of
SP
is
caused.
3.
Any
blistering
part
of
the
sticked
counter
name
plate
touches
the
top
cover
with
the
result
that
the
adhesives
are
pressed
out
and
touches
the
counter
SP
hook.
Repairing
technique
and
confirming
method
1.
When
the
movement
of
the
counter
G-1
is
not
smooth,
replace
it.
Z
After
tightening
the
counter
base,
hook
SP.
3.
If
the
name
plate
is
blistering,
peel
off
the
name
plate,
remove
the
adhesives
completely,
and
then
re-stick
the
name
plate.
Phenomenon
Although
the
winding
lever
is
operated,
the
film
counter
does
not
move
from
S,
or
advances
inter¬
mittently.
(If
pressing
the
back
cover,
the
counter
advances
normally.)
Cause
Because
the
back
cover
cannot
push
the
counter
release
lever
to
the
full,
the
counter
G-1
does
not
perfectly
engage
the
counter
gear.
Curving
deformation.
Repairing
technique
and
confirming
method
Visually
check
whether
the
phenomenon
is
caused
by
deformation
of
the
back
cover.
(When
winding
the
film
while
pressing
the
back
cover,
if
the
counter
advances,
there
occurs
a
curve.)
If
there
is
a
step
between
the
surface
of
the
lock
plate
cover
and
that
of
the
back
cover,
the
curved
portion
should
be
corrected.
Phenomenon
When
the
film
counter
counts
36
frames
or
less
and
the
back
cover
is
opened,
the
counter
is
not
catches
something
in
the
course
of
return.
Cause
1.
Tightening
of
the
top
cover
nut
causes
the
top
cover
to
press
the
counter
SP
hook,
so
that
the
counter
gear
returns
heavily.
Z
Dimensional
inaccuracy
of
the
counter
gear
holder
and
the
counter
gear
does
not
allow
the
counter
SP
hook
to
make
engagement.
3.
The
counter
reset
SP
gets
jammed
in
between
the
counter
SP
hook
and
the
gear.
The
reset
SP
protrudes
from
the
gear
and
becomes
entangled
with
the
SP
hook.
Repairing
technique
and
confirming
method
1,
and
Z
Loosen
the
top
cover
nut
little
by
little,
and
if
the
counter
returns,
replace
the
counter
SP
hook
with
a
new
one.
Confirm
that
there
is
a
play
between
the
counter
SP
hook
and
the
gear.
3.
Remove
the
counter
SP
hook
and
check
the
entanglement
of
SP.
If
there
is
a
play
in
the
counter
SP
hook,
or
the
counter
does
not
return
from
time
to
time
though
the
gear
is
operated
by
fingers,
press
the
end
of
the
side
without
notch
of
the
SP
hook
by
use
of
a
screw
driver.
Again
operate
the
gear
by
fingers.
The
protrusion
of
SP
is
caused
by
deformation
of
the
reset
SP;
correct
it
to
its
normal
shape
or
replace
it.
22

Related product manuals