EasyManua.ls Logo

YASKAWA DX100 - Page 375

YASKAWA DX100
554 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-135
155507-1CD
RE-CSO-A037
DX100
6 Convenient Functions
6.15 Analog Output Function Corresponding to Speed
According to the set value of the ARATION instruction, the output
characteristics for the relation between the operating speed and the
analog voltage are calculated. The analog output function corresponding
to speed is executed depending on these output characteristics.
The following graph shows the output characteristics.
Fig. 6-5:
Output Characteristics When Analog Output Function Corresponding to
Speed is Used
ARATIOF
When the ARATIOF instruction is executed, the analog output
corresponding to speed is completed, and the set offset voltage becomes
the fixed output.
ARATIOF AO#(1)
Output port number
General analog output port to end the analog output corresponding to
speed
Setting range : 1 to 40
NOTE
When the analog output value exceeds ± 14.00 V because
of the operating speed, the value is limited within ± 14.00 V.
Analog voltage
Operating
speed
Basic
speed
Basic
voltage
Offset
voltage
14V
0
375 of 554