6-139
155507-1CD
RE-CSO-A037
DX100
6 Convenient Functions
6.15 Analog Output Function Corresponding to Speed
6.15.2.3 Analog Output Display
The current settings can be confirmed on the analog output window.
Terminal
General analog output port
OUTPUT (V)
Indicates the voltage which is currently output.
BASIC (V)
Indicates the basic voltage used for the analog output corresponding to
speed.
This value is used until a new value is set by ARATION instruction.
TRAIT
Indicates the current output characteristics of the output port.
SP RAT : during execution of the analog output corresponding to speed
STATIC : fixed output status
OFFSET (V)
Indicates the offset voltage used for the analog output corresponding to
speed.
This value is used until a new value is set by ARATION instruction.
BASIC SPD
Indicates the basic speed used for the analog output corresponding to
speed.
This value is used until a new value is set by ARATION instruction.
ROBOT
Indicates the manipulator number for the analog output corresponding
to speed.
1. Select {IN/OUT} from the main menu
2. Select {ANALOG OUTPUT}
The analog output window appears.
The output terminal numbers which follow
the AOUT4 can be switched and
displayed by pressing the page key.