8 Parameter
8.9 TRANSMISSION PARAMETERS
8-55
155507-1CD
RE-CSO-A037
DX100
8.9 TRANSMISSION PARAMETERS
These parameters are used when the optional FC1, FC2, or data
transmission function is used.
For details, refer to the optional manual “DX100 DATA TRANSMISSION
FUNCTION”.
8.10 Application Parameters
8.10.1 Arc Welding
8.10.1.1 AxP000: APPLICATION
This parameter specifies the application. Set “0” for arc welding.
8.10.1.2 AxP003: WELDING ASSIGNMENT OF WELDING START CONDITION
FILE
This parameter specifies the beginning condition number in the welding
start condition file to be assigned to Power Source 2. Condition files of a
lower number are automatically assigned to Power Source 1. For a
system with one Power Source, set “49” (maximum value).
8.10.1.3 AxP004: WELDING ASSIGNMENT OF WELDING END CONDITION
FILES
This parameter specifies the beginning condition number in the welding
END condition file to be assigned to Power Source 2. Condition files of a
lower number are automatically assigned to Power Source 1. For a
system with one Power Source, set “13” (maximum value).
8.10.1.4 AxP005: WELDING SPEED PRIORITY
This parameter specifies whether the welding speed is specified by the
“ARCON” instruction, by the welding start condition file, or by the
additional times of the “MOV” instruction.
8.10.1.5 AxP009: WORK CONTINUING
This parameter specifies whether to output an “ARCON” instruction to
restart after the manipulator stopped while the “ARCON” instruction is
being output.
Condition file
Power
Source 1
Power
Source 2
Power
Source 1
Power
Source 2