EasyManua.ls Logo

YASKAWA DX100 - 3 Teaching; Preparation for Teaching; Checking Emergency Stop Buttons; Setting the Teach Lock

YASKAWA DX100
554 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Teaching
3.1 Preparation for Teaching
3-1
155507-1CD
RE-CSO-A037
DX100
3 Teaching
3.1 Preparation for Teaching
To ensure safety, the following operations should always be performed
before teaching:
• Check the emergency stop buttons to be sure they function properly.
• Set the mode switch to “TEACH”.
Then,
• Register a job.
3.1.1 Checking Emergency Stop Buttons
The Servo ON button on the programming pendant should be lit while the
power is ON for the servo system. Perform the following operation to
ensure that the emergency stop buttons on both the DX100 and the
programming pendant are functioning correctly before operating the
manipulator.
1. Press E. STOP button.
Press the emergency stop button on the DX100 or the programming
pendant.
2. Confirm the servo power is turned OFF.
The SERVO ON button on the programming pendant lights while
servo supply is turned ON.
When the emergency stop button is pressed and the servo power is
turned OFF, the SERVO ON lamp will turn OFF.
3. Press [SERVO ON READY] of the programming pendant.
After confirming correct operation, press [SERVO ON READY]. The
servo power will be ready to turn ON.
The servo power can be turned ON while the SERVO ON button
lamp blinks.
3.1.2 Setting the Teach Lock
For safety purposes, always set the mode switch to “TEACH” before
beginning to teach.
While the teach lock is set, the mode of operation is tied to the teach mode
and the machines cannot be played back using either [START] or external
input.
84 of 554