11 Modification of System Configuration
DX100 11.1 Addition of I/O Modules
11-2
5. Select {IO MODULE}.
– The current status of the mounted I/O module is shown.
6. Confirm the status of mounted I/O module.
– Confirm that each station (ST#) window is the same as the I/O
module’s actual mounting status.
– The following information is shown for each station.
1) A hyphen, -, indicates that the corresponding I/O section is not mounted.
2) If the system cannot recognize the circuit board type, a row of stars
(*****) are shown. No problem will occur as long as the values
displayed in DI, DO, AI, and AO are correct.
7. Press [ENTER].
– Confirm the statuses of the mounted I/O modules for the other
stations.
ST# Station address of I/O module
DI Number of contact input points
1)
DO Number of contact output points
1)
AI Number of analog input points
1)
AO Number of analog output points
1)
BOARD Circuit board type
2)