11 Modification of System Configuration
DX100 11.2 Addition of Base and Station Axes
11-13
<Phenomenon2>
During pause, the motor makes a lot of noise.
Confirm the motion with decreasing this ratio in each 100.
3. Modify the settings.
4. Press [ENTER] in the MOTOR SPEC window.
After the setting, the current window moves to the window for the
next axis setting. Complete the settings for all axes in the same
manner.
When [ENTER] is pressed in the MOTOR SPEC window for the last
axis, the setting in the MOTOR SPEC window is completed and the
confirmation dialog box appears.
If {YES} is selected, the system parameter is set automatically.
11.2.2 Station Axis Setting
11.2.2.1 Selection of Station Axis Type
Select the type of station axis to be added/modified.
1. Confirm the type of control group in CONTROL GROUP window.
The CONTROL GROUP window appears.