12 DX100 Specification
DX100 12.1 Specification List
12-2
12.1 Specification List
Controller Construction Free-standing, enclosed type
Dimensions Refer to following
Cooling System Indirect cooling
Ambient
Temperature
0°C to + 45°C (During operation)
-10°C to + 60°C (During transit and
storage)
Relative Humidity 10% to 90%RH (non-condensing)
Power Supply 3-phase, 200/220 VAC (+10% to -15%)
at 60Hz(±2%)
200 VAC(+10% to -15%) at 50Hz(±2%)
Grounding Grounding resistance: 100Ω or less
Exclusive grounding
Digital I/O Specific signal (hardware)
23 inputs and 5 outputs
General signals (standard, max.)
40 inputs and 40 outputs
(Transistor: 32 outputs, Relay: 8 outputs)
Positioning System By serial communication
(absolute encoder)
Drive Unit SERVOPACK for AC servomotors
Acceleration/
Deceleration
Software servo control
Memory Capacity 200000 steps, 10000 instructions
Small capacity
A-Type
(standard)
MA1400, MA1900, VA1400, MH5L, MH6, HP20D, HP20D-6,
425(W) × 1200(H) × 450(D) mm
Medium and
Large capacity
A-Type
(standard)
MH50, MS80, ES165D, ES200D, VS50
425(W) × 1200(H) × 450(D) mm