13 Description of Units and Circuit Boards
DX100 13.4 CPS Unit (JZNC-YPS01-E)
13-11
Items Specifications
Input
Rating Input Voltage: 200/220VAC
Voltage Fluctuation Range: +10% to -15% (170 to 242VAC)
Frequency: 50/60Hz ± 2Hz (48 to 62Hz)
Output Voltage
DC + 5V
DC +24V (24V1: System, 24V2: I/O, 24V3: Brake)
Indicator
Control Power
ON/OFF
To turn ON the DX100 controller power, turn ON the non-fuse breaker of the
controller so that the control power supply is turned ON. If the controller is not
located at the workplace, the control power supply can be turned ON/OFF by an
external device, etc. after the non-fuse breaker of the controller is turned ON. It is
operated by the external switch connected with CN152 of the CPS unit as shown in
the following figure. (CN152-1 and CN152-2 is shortaged when shipment)
Fig. 13-8: Connection to Control Power Supply Unit
See chapter 13.8 “WAGO Connector” at page 13-21 for wiring of CN152 connector.
DISPLAY Color Status
SOURCE Green Lights with power supply input.
Lights out when internal live part completes
discharge.
(Power supply status: being input)
POWER ON Green Lights when PWR_OK output signal is ON.
(Power supply status: being output)
+5V Red Lights with +5V over-current
(ON when abnormal)
+24V Red Lights with +24V over-current
(ON when abnormal)
FAN Red Lights when FAN error occurs.
OHT Red Lights when unit interior overheats
Remove the short-circuit positioner
Control Power Supply ON/OFF Switch
Control Power Supply
DX100
CPS-420F
CN152
R-IN
R-INCOM
-1
-2