13 Description of Units and Circuit Boards
DX100 13.10 Contact Output of Emergency Stop Button
13-34
13.10 Contact Output of Emergency Stop Button
The contact output terminals for the emergency stop button on the pro-
gramming pendant and the door front are provided on the terminal block
2XT (screw size M3.5) at lower part of the right side of DX100.
These contact outputs are always valid no matter of the DX100 main
power supply status ON or OFF. (Status output signal: normally closed
contact)
Fig. 13-21: Contact Output Terminal Block of Emergency Button (2XT)
CAUTION
• Do not use the emergency stop button with 24 VAC, 0.5 A or more.
Failure to observe this instruction may result in damage to equipment.
Emergency stop button
Emergency stop button
PBESP3+
PBESP3−
PPESP3+
PPESP3−
PBESP3+
PBESP3−
PPESP3+
PPESP3−
2XT
EXT
PBESP4+
PBESP4−
PBESP4+
PBESP4−
PPESP4+
PPESP4−
PPESP4+
PPESP4−
Front door of DX100
Programming pendant