13 Description of Units and Circuit Boards
DX100 13.12 Universal I/O Signal Assignment
13-65
30051
4)
WELD ERROR RESET
This signal commands the reset error status of the Power Source. This is operated
with the programing pendant operation.
30052 to
30056
4)
WELD CONDITION (Level signals)
1(1), 2(2), 4(3), 8(4), 16(5), 32(6), 64(7), 128(8)
Sets the welding conditions for the Power Source.
The output format can be selected as binary or discrete (bit number). It can handle up
to 255 conditions. Most-significant bit is the parity bit (when specified).
4)
WELDING COMMAND
This signal outputs execution command signal to the Power Source. This signal is not
necessary for a Power Source which is executed using the WELDING CONDITION
signal.
4)
STROKE CHANGE1
SINGLE SOLENOID
DOUBLE SOLENOID
This is a signal, when a double stroke gun is used, to change the open stroke of the
welding gun.
4)
GUN PRESS COMMAND
This outputs gun press command.
1 This signal is not output during operation.
2 The work home position cube and Cube 32 are same.
3 This signal can be select “USE” or “NOT USE” by pseudo input signal ”8202x”. If “NOT USE” is selected, this
signal can be used as the universal I/O signal described in parentheses.
4 This signal can be allocated to any universal I/O signal at the I/O allocation display in operation condition.
Table 13-13: Specific Output (Spot Welding) (Sheet 2 of 2)
Logical
Number
Output Name / Function
Timer Cooling Water Error Validating (or IN09)
Gun Cooling Water Error Validating (or IN10)
Transthermo Error Validating (or IN11)
Low Air Pressure Validating (or IN12)
Weld ON/OFF Validating (or OUT09)
7 6 5 4 3 2 1 0
0 0 0 1 1 1 1 1
Pseudo Input
Signal 8202x