4 Connection
DX100 4.2 Power Supply
4-3
4.2 Power Supply
4.2.1 Three-Phase Power Supply
The three-phase power supply consists of 200/220VAC at 60Hz and
200VAC at 50Hz.
Fig. 4-2: Input Power Connection
4.2.2 Noise Filter Installation
Insert the three-phase noise filter into the primary station of the non-fuse
breaker filter if you hear noise coming from the power source.
Seal up each cable opening so that dust does not enter.
Fig. 4-3: Connection of Three-Phase Noise Filter
NOTE
The power failure processing circuit operates when there is
a black out or drop in voltage, and the servo power turns
OFF.
Connect the power supply to a stable power source that is
not prone to power fluctuations.
SERVOPACK
1KM
2KM
Contactor
To control
power supply
unit
Noise Filter
Breaker
DX100
Fuse
3-phase
200/220VAC at 60Hz
or
200VAC 50Hz
SERVOPACK
Contactor
1KM
2KM
To control
power supply
unit
Noise Filter
DX100
Breaker
3-phase
Noise Filter
3-phase
200/220VAC at 60Hz
or
200VAC 50Hz
Fuse