Alarm List
Alarm Number (4000 to 4999)
Alarm List-883
4754 M-SAF EXESP DIAG.
ERROR
Sub code indicates the
process that the software of
CPU1 or CPU2 detected an
error.
YSF21 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YSF21 board.
YSF22 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YSF22 board.
In a system where a plurality of YSF22 boards are connected, replace
the YSF22 board which is connected to the first EAXA21 board.
Other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4755 M-SAF PP ENABLE
SW DIAG. ERROR
Sub code indicates the
process that the software of
CPU1 or CPU2 detected an
error.
YSF21 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YSF21 board.
YSF22 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YSF22 board.
In a system where a plurality of YSF22 boards are connected, replace
the YSF22 board which is connected to the first EAXA21 board.
Other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4756 M-SAF EX ENABLE
SW DIAG. ERROR
Sub code indicates the
process that the software of
CPU1 or CPU2 detected an
error.
YSF21 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YSF21 board.
YSF22 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YSF22 board.
In a system where a plurality of YSF22 boards are connected, replace
the YSF22 board which is connected to the first EAXA21 board.
Other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy