Alarm List
Alarm Number (0000 to 0999)
Alarm List-136
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
65 The software version of the
functional safety board
connected to the 6th servo
board is unmatched.
Software error (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the YSF25 board version and then
consult your Yaskawa representative.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
66 The software version of the
functional safety board
connected to the 7th servo
board is unmatched.
Software error (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the YSF25 board version and then
consult your Yaskawa representative.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
67 The software version of the
functional safety board
connected to the 8th servo
board is unmatched.
Software error (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the YSF25 board version and then
consult your Yaskawa representative.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
70 The software version of the
YSF21 board is unmatched.
Software error (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the YSF21 board version and then
consult your Yaskawa representative.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
0520 AXIS LIMIT OVER 0 Setting error (1)Check the following settings.
∙ Control group settings in maintenance mode
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy