Alarm List
Alarm Number (1000 to 1999)
Alarm List-359
1653 BASE BLOCK SIGNAL
ERROR(SERVO)
Sub Code: Signifies the axis
in which the alarm occurred
EAXA21 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the EAXA21 board. Save the
CMOS.BIN before replace the board to be safe.
Module failure (amplifier) (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the amplifier.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
1654 PG POWER ON
MULTIPLE REQ (SV)
Setting error Check if the PICK instruction was executed again for the axis where
executed the PICK instruction in the gun change system.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
1655 CONVERTER
COMMAND ERROR
(SV)
Module failure (converter) (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
1656 AXIS ENDLESS INFO
NOT
GENERATED(SV)
Setting error Check the JOB.
(1)Turn the power OFF then back ON.
(2)If the error occurs again, contact your Yaskawa representative.
1657 AXIS ENDLESS
SPECIFIC. ERR(SV)
1 The home position detecting
function was used for the axis
for which the axis endless
function was enabled.
The home position detecting
function cannot be used for
the axis which the axis
endless function was enabled.
Setting error Disable either the axis endless function or the home position detection
function of corresponding axis.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).