Alarm List
Alarm Number (1000 to 1999)
Alarm List-366
1681 BRAKE POWER
ERROR(SV)
Connection failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
YBK21-CN403
YPS21-CN153(+24V3)
Short circuit or ground
fault
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and inserting state
of the following cables and connectors.
Check the insertion, connection, Short circuit or ground fault of the
followings.
YFC22-CN219(81,82,92,93 : +24V2U3)
YFC22-CN219(83,84,94,95 : 024V2)
YIO-CN306,CN307,CN308,CN309
YBK board failure Check the power source of YBK21, and then if no fault is found,
replace the brake unit.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
1682 EXTERNAL BRAKE
POWER ERROR(SV)
Connection failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
YBK21-CN404
The external axis brake power supply for brake unit
Short circuit or ground
fault
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and inserting state
of the following cables and connectors.
Check the insertion, connection, Short circuit or ground fault of the
followings.
YFC22-CN219(81,82,92,93 : +24V2U3)
YFC22-CN219(83,84,94,95 : 024V2)
YIO-CN306,CN307,CN308,CN309
YBK board failure Check the external axis brake of YBK21 in the power source, and then
if no fault is found, replace the brake unit.