Alarm List
Alarm Number (1000 to 1999)
Alarm List-368
Connection failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
∙ EAXA21-CN501 to 506
∙ EAXB21-CN531,532,533
∙ Amplifier-CN581
∙ EX1SV(External axis servo pack)-CN591,595
Module failure (amplifier) (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the amplifier.
Module failure (motor) (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the motor.
EAXA21 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the EAXA21 board. Save the
CMOS.BIN before replace the board to be safe.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
1687 COORDINATED
STOP FUNC.
DISABLE
Setting error (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
1688 MEMORY DATA FILE
STORAGE ERROR
1 Storage file number is
inconsistent
Software operation error
occurred
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
2 Start index is inconsistent Software operation error
occurred
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
1690 PCI BOARD NOT
DETECTED
AD board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
Alarm
Number
Alarm Name Sub
Code