Alarm List
Alarm Number (4000 to 4999)
Alarm List-427
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4042 MEMORY ERROR
(VISION FILE)
Sub Code: Page number Data error (1)Reset the alarm.
(2)If the alarm occurs again, initialize the vision condition file in
maintenance mode, and then load the vision condition file saved in the
external memory device.
YCP21 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP21 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YCP21
board, and then insert the CF card which inserted original YCP21
board into the new YCP21 board.
YIF01 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF01 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YIF01
board, and then load the CMOS.BIN saved before alarm occurred.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4043 MEMORY ERROR
(VISION
CALIBRATION)
Sub Code: Page number Data error (1)Reset the alarm.
(2)If the alarm occurs again, initialize the vision calibration file in
maintenance mode, and then load the vision calibration file saved in
the external memory device.
YCP21 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP21 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YCP21
board, and then insert the CF card which inserted original YCP21
board into the new YCP21 board.
YIF01 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF01 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YIF01
board, and then load the CMOS.BIN saved before alarm occurred.
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy