Alarm List
Alarm Number (4000 to 4999)
Alarm List-536
92 A job data was destroyed. Software operation error
occurred
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were
executed, initialize the job file in the maintenance mode, and then load
the saved job file.
(4)If the error occurs again though the previous measures were
executed, save the CMOS.BIN in maintenance mode, and then contact
your Yaskawa representative about occurrence status (operating
procedure).
99 A job data in the memory was
destroyed.
Software operation error
occurred
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were
executed, initialize the job file in the maintenance mode, and then load
the saved job file.
(4)If the error occurs again though the previous measures were
executed, save the CMOS.BIN in maintenance mode, and then contact
your Yaskawa representative about occurrence status (operating
procedure).
4203 SYSTEM ERROR
(POSITION DATA)
-1 The memory area for position
data is lacking at the
initialization of the position
data control process.
Software operation error
occurred
Reset the alarm, and then try again.
YIF01 board failure (1)Reset the alarm, and then try again.
(2)If the alarm occurs again, replace the YIF01 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YIF01
board, and then load the CMOS.BIN saved before alarm occurred.
YCP21 board failure (1)Reset the alarm, and then try again.
(2)If the alarm occurs again, replace the YCP21 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YCP21
board, and then insert the CF card which inserted original YCP21
board into the new YCP21 board.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy