EasyManua.ls Logo

YASKAWA DX200 - Page 903

YASKAWA DX200
1166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alarm List
Alarm Number (4000 to 4999)
Alarm List-682
54 Err054
Sub code[54**] shows the
error code of Fronius power
source
54:main error code
**:sub error code
Arc welding power source
error
Increase the bbc (burn-back control)
Switch off "Wire stick" in the set-up menu
After the end of welding, make sure that the wire does not collide with
the workpiece when the torch is retracted.
Confirm the Fronius's manual.
55 NoIGn
Sub code[55**] shows the
error code of Fronius power
source
55:main error code
**:sub error code
Arc welding power source
error
Set a lower Ito value
Keep the torch stand-off distance smaller before ignition.
Confirm the Fronius's manual.
56 Err056
Sub code[56**] shows the
error code of Fronius power
source
56:main error code
**:sub error code
Arc welding power source
error
Check how much wire is left on the spool
If necessary, change the spool.
Confirm the Fronius's manual.
57 NoGAS
Sub code[57**] shows the
error code of Fronius power
source
57:main error code
**:sub error code
Arc welding power source
error
Check what volume of gas is still available.
Confirm the Fronius's manual.
58 NoArc
Sub code[58**] shows the
error code of Fronius power
source
58:main error code
**:sub error code
Arc welding power source
error
Check the seam.
Confirm the Fronius's manual.
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy

Table of Contents

Other manuals for YASKAWA DX200

Related product manuals