EasyManua.ls Logo

YASKAWA GA500 series - Page 578

YASKAWA GA500 series
794 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12.5 d: References
578 YASKAWA SIEPC71061753C GA500 Technical Manual
d4-08: Up/Down 2 Bias Upper Limit
No.
(Hex.)
Name Description
Default
(Range)
d4-08
(02AF)
RUN
Up/Down 2 Bias Upper
Limit
Sets the upper limit of the Up/Down 2 bias as a percentage of the Maximum Output Frequency.
100.0%
(0.0 - 100.0%)
The drive saves the set bias upper limit in d4-06 [Frequency Ref Bias (Up/Down 2)]. Set d4-08 an applicable
value before you use the Up/Down 2 function.
Note:
When d4-01 = 1 [Freq Reference Hold Selection = Enabled] and b1-01 = 0 [Frequency Reference Selection 1 = Keypad], the drive will
add the bias value to the frequency reference when it does not receive an Up/Down 2 command for 5 s. Then the drive will reset the
value to 0 at which time you can increase the bias to the limit set in d4-08 again.
d4-09: Up/Down 2 Bias Lower Limit
No.
(Hex.)
Name Description
Default
(Range)
d4-09
(02B0)
RUN
Up/Down 2 Bias Lower
Limit
Sets the lower limit of the Up/Down 2 bias as a percentage of the Maximum Output Frequency.
0.0%
(-99.9 - 0.0%)
The drive saves the set bias lower limit in d4-06 [Frequency Ref Bias (Up/Down 2)]. Set d4-09 to an applicable
value before you use the Up/Down 2 function.
Note:
When d4-01 = 1 [Freq Reference Hold Selection = Enabled] and b1-01 = 0 [Frequency Reference Selection 1 = Keypad], the drive will
add the bias value to the frequency reference when it does not receive an Up/Down 2 command for 5 s. Then the drive will reset the
value to 0.
If you increase the bias with the Up 2 command and d4-09 = 0, you cannot use a Down 2 command to decrease the frequency reference.
To decrease speed in this condition, set a negative lower limit in d4-09.
d4-10: Up/Down Freq Lower Limit Select
No.
(Hex.)
Name Description
Default
(Range)
d4-10
(02B6)
Up/Down Freq Lower Limit
Select
Sets the lower frequency limit for the Up/Down function.
0
(0, 1)
0 : Greater of d2-02 or Analog
The higher value between d2-02 [Frequency Reference Lower Limit] and an analog input programmed for
Frequency Reference [H3-02, H3-10 = 0] sets the lower frequency reference limit.
Note:
When you use External Reference 1/2 Selection [H1-xx = 2] to switch between the Up/Down function and an analog input as the
reference source, the analog value becomes the lower reference limit when the Up/Down command is active. Set d4-10 = 1 to isolate the
Up/Down function and the analog input value.
1 : d2-02
You can only use d2-02 to set the lower limit of the frequency reference.
d4-11: Bi-directional Output Selection
No.
(Hex.)
Name Description
Default
(Range)
d4-11
(02B7)
Bi-directional Output
Selection
Sets the function that changes the frequency reference to a Bi-Directional internal frequency
reference.
0
(0, 1)
0 : Disabled
The drive will not change the frequency reference or PID output value to Bi-Directional internal frequency
reference.
When the frequency reference or PID output value is 0% to 100% of the maximum output frequency, the drive
runs the motor in the set direction.
1 : Enabled
Changes the frequency reference or PID output value to Bi-Directional output.
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV
V/f
OLV
OLV/PM OLV/PM
AOLV/PM
EZOLV

Table of Contents

Other manuals for YASKAWA GA500 series

Related product manuals