Parameter Details
11
11.11 o: Keypad-Related Settings
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 1013
o1-05: LCD Contrast Adjustment
No.
(Hex.)
Name Description
Default
(Range)
o1-05
(0504)
RUN
LCD Contrast
Adjustment
Sets the contrast of the LCD display on the keypad.
5
(0 - 10)
When you decrease the setting value, the contrast of the LCD display decreases. When you increase the setting
value, the contrast increases.
o1-10: User Units Maximum Value
No.
(Hex.)
Name Description
Default
(Range)
o1-10
(0520)
User Units Maximum
Value
Sets the value that the drive shows as the maximum output frequency.
Determined by o1-03
(1 - 60000)
To display a maximum output frequency of 100.00, set parameters to these values:
o1-10 = 10000
o1-11 = 2 [User Units Decimal Position = 2 Dec (XXX.XX)]
Note:
Set o1-03 = 3 [Keypad Display Selection = User-selected units] before you set o1-10 and o1-11.
o1-11: User Units Decimal Position
No.
(Hex.)
Name Description
Default
(Range)
o1-11
(0521)
User Units Decimal
Position
Sets the number of decimal places for frequency reference and monitor
values.
Determined by o1-03
(0 - 3)
0 : No Decimal Places (XXXXX)
1 : One Decimal Places (XXXX.X)
2 : Two Decimal Places (XXX.XX)
3 : Three Decimal Places (XX.XXX)
Note:
Set o1-03 = 3 [Keypad Display Selection = User-selected units] before you set o1-10 [User-Set Display Units Max Value] and o1-11.
o1-24 to o1-35: Custom Monitor 1 to 12
No.
(Hex.)
Name Description
Default
(Range)
o1-24 to o1-
35
(11AD -
11B8)
RUN
Custom Monitor 1 to
12
Sets a maximum of 12 monitors as user monitors. This parameter is only
available with an LED keypad.
o1-24: 101
o1-25: 102
o1-26: 103
o1-27 to o1-35: 0
(0, 101 - 999)
These parameters save the monitor items selected by the LCD keypad [Custom Monitor].
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV