The frequency reference changes when you enter it with the keypad. This then changes the output frequency. It is
not necessary to push . The drive keeps the frequency reference for 5 seconds after you use and on
the keypad to change the frequency reference value.
■ o2-06: Keypad Disconnect Detection
No.
(Hex.)
Name Description
Default
(Range)
o2-06
(050A)
Keypad Disconnect
Detection
Sets the function that stops the drive if you disconnect the keypad
connection cable from the drive or if you damage the cable while the
keypad is the Run command source.
Determined by o2-09
(0, 1)
This parameter continues to operate if the keypad installed to the drive becomes disconnected.
This parameter is enabled in these conditions:
• When b1-02 = 0 [Run Command Selection 1 = Keypad] or b1-16 = 0 [Run Command Selection 2 = Keypad]
• In LOCAL Mode
0 : Disabled
The drive continues operation when it detects a keypad disconnection.
1 : Enabled
The drive stops operation, detects oPr [Keypad Connection Fault], and the motor coasts to stop when the drive
detects a keypad disconnection.
■ o2-07: Keypad RUN Direction @ Power-up
No.
(Hex.)
Name Description
Default
(Range)
o2-07
(0527)
Keypad RUN
Direction @ Power-
up
Sets the direction of motor rotation when the drive is energized and the
keypad is the Run command source.
0
(0, 1)
This parameter is enabled in these conditions:
• When b1-02 = 0 [Run Command Selection 1 = Keypad] or b1-16 = 0 [Run Command Selection 2 = Keypad]
• In LOCAL Mode
0 : Forward
1 : Reverse
■ o2-09: Region Code
No.
(Hex.)
Name Description
Default
(Range)
o2-09
(050D)
Region Code - -
■ o2-23: External 24V Powerloss Detection
No.
(Hex.)
Name Description
Default
(Range)
o2-23
(11F8)
External 24V
Powerloss Detection
Sets the function to give a warning when the backup external 24 V power
supply turns off when the main circuit power supply is in operation.
0
(0, 1)
Note:
The drive will not run when it is operating from one 24-V external power supply.
0 : Disabled
The drive does not detect the loss of the 24-V external power supply.
1 : Enabled
The keypad shows the L24v [Ext. 24-V Power Supply Lost] indicator when the drive detects the loss of the 24-V
external power supply.