EasyManua.ls Logo

YASKAWA GA700 - Page 274

YASKAWA GA700
1053 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.3 UL Standards
274 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Drive Model
Maximum Applicable Motor
Output
kW (HP)
Input Current Rating
A
Semiconductor Protection
Fuse Rated Current
Manufacturer: EATON/
Bussmann
2012 2.2 (3) 12.7 FWH-100B
2018 3 (4) 17 FWH-100B
2021 3.7 (5) 20.7 FWH-100B
2030 5.5 (7.5) 30 FWH-125B
2042 7.5 (10) 40.3 FWH-150B
2056 11 (15) 58.2 FWH-200B
2070 15 (20) 78.4 FWH-225A
2082 18.5 (25) 96
FWH-225A
FWH-250A
*1
2110 22 (30) 82
FWH-225A
FWH-250A
*1
2138 30 (40) 111
FWH-275A
FWH-300A
*1
2169 37 (50) 136
FWH-275A
FWH-350A
*1
2211 45 (60) 164
FWH-325A
FWH-450A
*1
2257 55 (75) 200 FWH-600A
2313 75 (100) 271 FWH-800A
2360 90 (125) 324 FWH-1000A
2415 110 (150) 394 FWH-1000A
*1 Yaskawa recommends a fuse with a large rated current for applications with repeated loads.
Table 4.16 Factory-Recommended Branch Circuit Protection: 400 V Class (ND)
Drive Model
Maximum Applicable
Motor Output
kW (HP)
Input Voltage < 460 V
Maximum Applicable
Motor Output
kW (HP)
Input Voltage 460 V
Input Current Rating
A
Semiconductor
Protection Fuse Rated
Current
Manufacturer: EATON/
Bussmann
4002 0.75 (1) 0.75 (1) 2.5 FWH-50B
4004 1.5 (2) 1.5 (2) 4.7 FWH-50B
4005 2.2 (3) 2.2 (3) 6.7 FWH-50B
4007 3.0 (4) 3.0 (4) 8.9 FWH-60B
4009 4.0 (5) 3.7 (5) 11.7 FWH-60B
4012 5.5 (7.5) 5.5 (7.5) 15.8 FWH-60B
4018 7.5 (10) 7.5 (10) 21.2 FWH-80B
4023 11 (15) 11 (15) 30.6 FWH-90B
4031 15 (20) 15 (20) 41.3 FWH-150B
4038 18.5 (25) 18.5 (25) 50.5 FWH-200B
4044 22 (30) 22 (30) 59.7 FWH-200B
4060 30 (40) 30 (40) 58.3 FWH-225A
4075 37 (50) 37 (50) 71.5 FWH-250A
4089 45 (60) 45 (60) 86.5 FWH-275A
4103 55 (75) 55 (75) 105 FWH-275A
4140 75 (100) 75 (100) 142 FWH-300A

Table of Contents