EasyManua.ls Logo

YASKAWA GA700 - Error Codes

YASKAWA GA700
1053 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Network
Communications
5
5.3 MEMOBUS/Modbus Communications
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual 325
Minor
Fault/
Alarm
Code
(Hex.)
Name
000B EF5 [External Fault (Terminal S5)]
000C EF6 [External Fault (Terminal S6)]
000D EF7 [External Fault (Terminal S7)]
000E EF8 [External Fault (Terminal S8)]
000F FAn [Internal Fan Fault]
0010 oS [Overspeed]
0011 dEv [Speed Deviation]
0012 PGo [Encoder (PG) Feedback Loss]
0014 CE [Modbus Communication Error]
0015 bUS [Option Communication Error]
0016 CALL [Serial Comm Transmission Error]
0017 oL1 [Motor Overloaded]
0018 oL2 [Drive Overloaded]
001A EF0 [Option Card External Fault]
001B rUn [Motor Switch during Run]
001D CALL [Serial Comm Transmission Error]
001E UL3 [Undertorque Detection 1]
001F UL4 [Undertorque Detection 2]
0020 SE [Modbus Test Mode Error]
0021 L24v [Loss of External Power 24 Supply]
0022 oH3 [Motor Overheat (PTC Input)]
0027 FbL [PID Feedback Loss]
0028 FbH [Excessive PID Feedback]
002A dnE [Drive Disabled]
002B PGoH [Encoder (PG) Hardware Fault]
Minor
Fault/
Alarm
Code
(Hex.)
Name
0031 E5 [MECHATROLINK Watchdog Timer Err]
0032 AEr [Station Address Setting Error]
0033 CyC [MECHATROLINK CommCycleSettingErr]
0034 HCA [High Current Alarm]
0035 LT-1 [Cooling Fan Maintenance Time]
0036 LT-2 [Capacitor Maintenance Time]
0039 EF1 [External Fault (Terminal S1)]
003A EF2 [External Fault (Terminal S2)]
003B SToF [Safe Torque OFF Hardware]
003C STo [Safe Torque OFF]
003D oL5 [Mechanical Weakening Detection 1]
003E UL5 [Mechanical Weakening Detection 2]
0042 TrPC [IGBT Maintenance Time (90%)]
0043 LT-3 [SoftChargeBypassRelay MainteTime]
0044 LT-4 [IGBT Maintenance Time (50%)]
0045 boL [Braking Transistor Overload]
0049 dWAL [DriveWorksEZ Alarm]
004A dWA2 [DriveWorksEZ Alarm 2]
004B dWA3 [DriveWorksEZ Alarm 3]
0081 EP24v [External Power 24V Supply]
0085 bAT [Keypad Battery Low Voltage]
0087 CP1 [Comparator 1 Limit Error]
0088 CP2 [Comparator 2 Limit Error]
0089 TiM [Keypad Time Not Set]
008A bCE [Bluetooth Communication Error]
Error Codes
MEMOBUS/Modbus Communications Error Code List
Table 5.16 lists the MEMOBUS/Modbus communications error codes.
When an error occurs, remove the cause of the error and restart communications.
Table 5.16 MEMOBUS/Modbus Communications Error Codes
Error Code
(Hex.)
Name Cause
01 Function Code Error The PLC set a function code that was not 03, 08, or 10 (Hex.)
02
Register Number
Error
The register number that is trying to access is not registered.
A starting number that was not 0001 or 0002 (Hex.) was set when broadcasting.
03 Bit Count Error
Read and write data quantities are more than the 1 to 16 range. (Command message data
quantity is disabled.)
The data that was read from non-consecutive holding registers contained more than 120 bytes.
The data to be written to non-consecutive holding registers contained more than 60 bytes.
In the write mode, the number of bytes in the message is not the number of data × 2.
21 Data Setting Error
Writing control data or parameters made the settings go out of the permitted setting range.
A parameter setting error occurred when writing a parameter.