9.4 Model Specifications (400 V Class)
454 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Table 9.8 Rating (400 V Class)
Model Input Voltage Duty Rating 4453 4568 4675
Maximum Applicable Motor Output
(kW)
< 460 V
*1
HD1 220 250 315
ND1 250 315 355
≧ 460 V
*2
HD2 260 300 335
ND2 300 335 370
Maximum Applicable Motor Output
(HP)
< 460 V
*1
HD1 300 335 400
ND1 335 400 450
≧ 460 V
*2
HD2 350 400 450
ND2 400 450 500
Input
Rated Input
Current
*3
(A)
< 460 V
HD1 (AC) 410 465 584
HD1 (DC) 502 569 715
ND1 (AC) 465 584 657
ND1 (DC) 569 715 805
≥ 460 V
HD2 (AC) 403 460 516
HD2 (DC) 494 563 632
ND2 (AC) 460 516 573
ND2 (DC) 563 632 702
Outputs
Rated Output
Capacity (kVA)
< 460 V
*4
HD1 272 298 398
ND1 298 374 444
≧ 460 V
*5
HD2 330 380 410
ND2 380 410 482
Rated Output
Current (A)
< 460 V
HD1 414 453 605
ND1 453 568 675
≥ 460 V
HD2 414 477 515
ND2 477 515 605
Overload Tolerance
• HD: 150% of the rated output current for 60 seconds
• ND: 110% of the rated output current for 60 seconds
Note:
Derating may be necessary for applications that start
and stop frequently.
Carrier Frequency
HD: 2 kHz without derating the drive capacity.
ND: 2 kHz without derating the drive capacity.
Derate the drive capacity to use values to 5 kHz
maximum.
Maximum Output Voltage
Three-phase 380 V to 480 V
Note:
The maximum output voltage is proportional to the
input voltage.
Maximum Output Frequency
• Advanced Open Loop Vector Control (AOLV) and EZ
Open Loop Vector Control (EZOLV): 120 Hz
• Closed Loop V/f Control (CL-V/f), Closed Loop Vector
Control (CLV), Advanced Open Loop Vector Control
for PM (AOLV/PM), and Closed Loop Vector Control
for PM (CLV/PM): 400 Hz
• V/f Control (V/f), Open Loop Vector Control (OLV),
and Open Loop Vector Control for PM (OLV/PM): 590
Hz
Measures for
Harmonics
DC Reactor Standard internal characteristics
Braking Device Braking Transistor External options