10.7 d: Reference Settings
524 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
d7: Offset Frequency
No.
(Hex.)
Name Description
Default
(Range)
Ref.
d7-01
(02B2)
RUN
Offset Frequency 1
Sets the value to add to or subtract from the frequency reference
when H1-xx = 44 [MFDI Function Select = Add Offset Frequency 1
(d7-01)] as a percentage of E1-04 [Maximum Output Frequency].
0.0%
(-100.0 - +100.0%)
796
d7-02
(02B3)
RUN
Offset Frequency 2
Sets the value to add to or subtract from the frequency reference
when H1-xx = 45 [MFDI Function Select = Add Offset Frequency 2
(d7-02)] as a percentage of E1-04 [Maximum Output Frequency].
0.0%
(-100.0 - +100.0%)
797
d7-03
(02B4)
RUN
Offset Frequency 3
Sets the value to add to or subtract from the frequency reference
when H1-xx = 46 [MFDI Function Select = Add Offset Frequency 3
(d7-03)] as a percentage of E1-04 [Maximum Output Frequency].
0.0%
(-100.0 - +100.0%)
797