10.10 H: Terminal Functions
554 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
No.
(Hex.)
Name Description
Default
(Range)
Ref.
H2-31
(154B)
Comparator 2 Off-
Delay Time
Sets the off-delay time for comparator 2.
0.0 s
(0.0 - 600.0 s)
893
H2-32
(159A)
Comparator 1
Filter Time
Sets the time constant that is applied to the primary delay filter used
for the analog output of the monitor selected with H2-20
[Comparator 1 Monitor Selection].
0.0s
(0.0 - 10.0 s)
893
H2-33
(159B)
Comparator1
Protection
Selection
Sets drive operation when it detects CP1 [Comparator1 Limit
Fault].
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : Digital Output Only
4
(0 - 4)
893
H2-34
(159C)
Comparator 2
Filter Time
Sets the time constant that is applied to the primary delay filter used
for the analog output of the monitor selected with H2-26
[Comparator 2 Monitor Selection].
0.0s
(0.0 - 10.0 s)
893
H2-35
(159D)
Comparator2
Protection
Selection
Sets drive operation when it detects CP2 [Comparator2 Limit
Fault].
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : Digital Output Only
4
(0 - 4)
893
H2-36
(159E)
Comparator 1
Ineffective Time
Sets the length of time that CP1 [Comparator1 Limit Fault] is
disabled.
0.0 s
(0.0 - 10.0 s)
894
H2-37
(159F)
Comparator 2
Ineffective Time
Sets the length of time that CP2 [Comparator2 Limit Fault] is
disabled.
0.0 s
(0.0 - 10.0 s)
894
H2-40
(0B58)
Mbus Reg 15E0h
bit0 Output Func
Sets the MFDO for bit 0 of MEMOBUS register 15E0 (Hex.).
F
(0 - 1A7)
894
H2-41
(0B59)
Mbus Reg 15E0h
bit1 Output Func
Sets the MFDO for bit 1 of MEMOBUS register 15E0 (Hex.).
F
(0 - 1A7)
894
H2-42
(0B5A)
Mbus Reg 15E0h
bit2 Output Func
Sets the MFDO for bit 2 of MEMOBUS register 15E0 (Hex.).
F
(0 - 1A7)
894
H2-60
(1B46)
Expert
Term M1-M2
Secondary
Function
Selects the second function for terminal M1-M2. The logical
calculation results of the terminals assigned to functions by H2-01
[Term M1-M2 Function Selection] is output.
F
(0 - A7)
895
H2-61
(1B47)
Expert
Terminal M1-M2
Logical Operation
Sets the logical operation for the functions set in H2-01 [Term M1-
M2 Function Selection] and H2-60 [Term M1-M2 Secondary
Function].
0
(0 - 8)
895
H2-62
(1B48)
Expert
Terminal M1-M2
Delay Time
Sets the minimum on time used to output the logical calculation
results from terminal M1-M2.
0.1 s
(0.0 - 25.0 s)
895
H2-63
(1B49)
Expert
Term M3-M4
Secondary
Function
Selects the second function for terminal M3-M4. The logical
calculation results of the terminals assigned to functions by H2-02
[Term M3-M4 Function Selection] is output.
F
(0 - A7)
895
H2-64
(1B4A)
Expert
Terminal M3-M4
Logical Operation
Sets the logical operation for the functions set in H2-02 [Term M3-
M4 Function Selection] and H2-63 [Term M3-M4 Secondary
Function].
0
(0 - 8)
895