11.8 H: Terminal Functions
902 YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Figure 11.98 Example of User-set Speed Agree 2 (L4-03 Is Positive)
15: Frequency Detection 3
Setting Function Description
15 Frequency Detection
3
The terminal deactivates when the output frequency is higher than the setting value of L4-03
[Speed Agree Detect Level (+/-)] + L4-04 [Speed Agree Detect Width (+/-)]. After the terminal
deactivates, the terminal stays off until the output frequency is at the value of L4-03.
Note:
The detection level set with L4-03 is a signed value. The drive will only detect in one direction.
CLV and CLV/PM control use motor speed as the reference.
ON : The output frequency is less than the value of L4-03 or is not higher than the value of L4-03
+ L4-04.
OFF : The output frequency is higher than the value of L4-03 + L4-04.
Figure 11.99 Example of Frequency Detection 3 (value of L4-03 Is Positive)
Note:
Figure 11.99 shows the result of the configuration when L4-07 = 1 [Speed Agree Detection Selection = Detection Always Enabled]. The
default setting of L4-07 is 0 [No Detection during Baseblock]. When the speed agreement detection selection is No Detection during
Baseblock, the terminal is deactivated when the drive output stops.
16: Frequency Detection 4
Setting Function Description
16 Frequency Detection
4
The terminal activates when the output frequency is higher than the value of L4-03 [Speed Agree
Detect Level (+/-)]. After the terminal activates, the terminal stays on until the output frequency is
at the value of L4-03 - L4-04.
Note:
The detection level set with L4-03 is a signed value. The drive will only detect in one direction.
CLV control uses motor speed as the reference.
ON : The output frequency is higher than the value of L4-03.
V/f