Parameter List
1
1.21 Defaults by Drive Model and Duty Rating ND/HD
YASKAWA TOEPYAIGA8002B GA800 Drive Programming 149
No. Name Unit Default
- Drive Model - 4371 4414 4477 4568
C6-01
Normal /
Heavy Duty
Selection
-
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04
Drive Model
(KVA)
Selection
Hex. A9 AA AC AD
E2-11
(E4-11, E5-
02)
Motor Rated
Power
HP (kW)
200
(160)
250
(200)
250
(200)
300
(220)
300
(220)
335
(250)
335
(250)
400
(315)
L8-09
Output Ground
Fault
Detection
- 1 1 1 1 1 1 1 1
L8-38
Carrier
Frequency
Reduction
- 2 2 2 2 2 2 2 2
n1-01
Hunting
Prevention
Selection
- 2 2 2 2 2 2 2 2
n1-03
Hunting
Prevention
Time Constant
ms 30 30 100 100 100 100 100 100
n5-02
Motor Inertia
Acceleration
Time
s 0.777 0.864 0.864 0.91 0.91 1.392 1.392 1.392
*1 Parameters within parentheses are for motor 2.
No. Name Unit Default
- Drive Model - 4605 4720
C6-01
Normal / Heavy Duty
Selection
-
HD ND HD ND
0 1 0 1
o2-04
Drive Model (KVA)
Selection
Hex. AE AF
E2-11
(E4-11, E5-02)
Motor Rated Power HP (kW)
400
(315)
450
(355)
400
(315)
500
(370)
b3-04
V/f Gain during Speed
Search
% 60 60 60 60
b3-06
Speed Estimation
Current Level 1
- 0.7 0.7 0.7 0.7
b3-08
Speed Estimation ACR
P Gain
- 0.8 0.8 0.8 0.8
b3-26
Direction Determination
Level
- 1000 1000 1000 1000
b8-03
Energy Saving Filter
Time
s 2.00 2.00 2.00 2.00
b8-04
Energy Saving
Coefficient Value
- 21.76 23.84 21.76 23.84
C5-17
(C5-37)
Motor Inertia kgm
2
11.00 12.00 11.00 12.00
C6-02
Carrier Frequency
Selection
- 1 7 1 7
E2-01
(E4-01)
Motor Rated Current
(FLA)
A 500 650 500 650
E2-02
(E4-02)
Motor Rated Slip Hz 1.25 1 1.25 1
E2-03
(E4-03)
Motor No-Load Current A 130 130 130 130
E2-05
(E4-05)
Motor Line-to-Line
Resistance
Ω 0.014 0.012 0.014 0.012