Setting Function Page
61
External Speed Search
command 1
62
External Speed Search
command 2
63 Field weakening
65 KEB Ride-Thru 1 (N.C.)
66 KEB Ride-Thru 1 (N.O.)
67 Communications test mode
68 High Slip Braking (HSB)
6A Drive enable
73 Low City Press
75 Up 2 command
76 Down 2 command
7A KEB Ride-Thru 2 (N.C.)
7B KEB Ride-Thru 2 (N.O.)
80 HAND Mode
81 HAND Mode 2
88 Volute-Thermostat Normally Open
Setting Function Page
89 Volute-Thermostat Normally Closed
8C Disable Pre-Charge
8D Multi Setpoint 1
8E Multi Setpoint 2
8F Low Water Level
90 High Water Level
92 Reset Accum
95 Remove Drive Disable
A8 Secondary PI Disable (N.O.)
A9 Secondary PI Disable (N.C.)
AA Secondary PI Inverse Operation
AB Secondary PI Integral Reset
AC Secondary PI Integral Hold
AD Select Secondary PI Parameters
AF Emergency Override Forward Run
B0 Emergency Override Reverse Run
n
H2-01 to H2-03: Terminal M1-M2, M3-M4, and MD-ME-MF Function Selection
The drive has three multi-function output terminals. Table 4.21 lists the functions available for theses terminals using H2-01,
H2-02, and H2-03.
No. Parameter Name Setting Range Default
H2-01 Terminal M1-M2 Function Selection (relay) 0 to 192 37: During Frequency Output
H2-02 Terminal M3-M4 Function Selection (relay) 0 to 192 F: Through Mode
H2-03 Terminal MD-ME-MF Function Selection (relay) 0 to 192 E: Fault
Table 4.21 Multi-Function Digital Output Terminal Settings
Setting Function Page
0 During run
1 Zero speed
2 Speed agree 1
3 User-set speed agree 1
4 Frequency detection 1
5 Frequency detection 2
6 Drive ready
7 DC bus undervoltage
8 During baseblock (N.O.)
9 Frequency reference source
A Run command source
B Torque detection 1 (N.O.)
C Frequency reference loss
D Braking resistor fault
E Fault
F Through mode
10 Minor fault
11 Fault reset command active
12 Timer output
13 Speed agree 2
14 User-set speed agree 2
15 Frequency detection 3
16 Frequency detection 4
Setting Function Page
17 Torque detection 1 (N.C.)
18 Torque detection 2 (N.O.)
19 Torque detection 2 (N.C.)
1A During reverse
1B During baseblock (N.C.)
1E Restart enabled
1F Motor overload alarm (oL1)
20 Drive overheat pre-alarm (oH)
22 Mechanical weakening detection
2F Maintenance period
30 During torque limit
37 During frequency output
38 Drive enabled
39 Watt hour pulse output
3C LOCAL/REMOTE status
3D During speed search
3E PID feedback low
3F PID feedback high
4A During KEB Ride-Thru
4C During fast stop
4D oH Pre-alarm time limit
4E Braking transistor fault (rr)
4F Braking resistor overheat (oH)
4.6 Basic iQpump Setup and Application Preset Parameters